Solarmeter 6.2 UVB Radiometer

This product is covered by our Safe Delivery Guarantee

£224.99
€268.46
$286.34
$383.56
DKK2,003.76
NOK2,411.67
SEK2,633.64
$380.26
RRP £249.99 Save £25.00
RRP €298.29 Save €29.83
RRP $318.16 Save $31.82
RRP $426.18 Save $42.62
RRP DKK2,226.41 Save DKK222.65
RRP NOK2,679.64 Save NOK267.98
RRP SEK2,926.28 Save SEK292.64
RRP $422.51 Save $42.25
You save £25.00
You save €29.83
You save $31.82
You save $42.62
You save DKK222.65
You save NOK267.98
You save SEK292.64
You save $42.25

Solarmeter 6.2 UVB Radiometer

Product Code: CSR062

Solarmeter 6.2 UVB Radiometer
   

More product images

Solarmeter 6.2 UVB RadiometerSolarmeter 6.2 UVB Radiometer

Printer Friendly

Download the Buying Guide

Download the Technical Guide

 
Description
Reviews
Delivery
Features
  • Integral Sensor.
  • Compact.
  • Durable.
  • Accurate.
  • LCD readout.


Applications
  • Lamp UVB Intensity and Aging.
  • Reptile Lamps.
  • Acrylic Shield Transmission.
  • Percent (%) UVB if divided by reading from Model 5.7 (UVA + B).
  • Eyewear UV block comparison.


Solarmeter Specifications
Model - 6.2
Irrad. Range - 0-1999 microW/cm² UVB
Response - 280-320 nm
Resolution - 1 microW/cm²
Conv. Rate - 3.0 Readings/Sec
Display - 3.5 Digit LCD
Digit Size - 0.4 inch high
Oper. Temp - 32° F TO 90° F
Oper. Humid. - 5% TO 80% RH
Accuracy - ±10% REF.NIST
Dimensions (in.) - 4.2L x 2.4W x 0.9D (in.)
Weight - 4.5 OZ. (incl. batt.)
Power Source - 9-Volt DC Battery
Lens - UV Glass
Diffuser - Virgin Teflon .003

Sensor
Silicon Carbide (SIC) Photodiode packaged in hermetically sealed UV glass window cap. Interference filter coating (Metal Oxide) blocks most UVA from response as shown on Spectral Sensitivity Graph.

Operation
Press and hold push-button switch on face of unit. Aim sensor window in top panel of meter directly at UV source. Note reading on LCD and record if desired. For reptile lamps also check at basking position.

Battery operation voltage is 9V down to 6.5V. Below 6.5V the LCD numbers will begin to dim, indicating the need for battery replacement. Under typical service load, the battery should last about 2 years.

Proper Usage of Solarmeter Ultraviolet Radiometer for Lamp Aging Tests
  • Wear eye protection when checking UV lamps (UV-block wrap around glasses).
  • Allow lamps to warm-up prior to taking readings (at least 5 min).
  • When checking aging of lamps, keep measuring distance and locations constant.
  • Lamps should be replaced when output drops 30% to about 70% of their original (new) readings. Take overall reading at exposure distance, or check individual lamps close to surface. Keep track of hours vs. readings on a chart.
  • If unsure of what original new values were, replace lamp(s) with new ones of the same kind and compare to old ones.
  • To determine percent UVB divide Model 6.2 reading by Model 5.7 total UV (UVA + B) reading. (See FAQ page).
  • When checking UVT acrylic transmission, take reading through acrylic; then remove acrylic and hold meter sensor at approximately the same distance from lamp as the acrylic shield was located. If acrylic blocks much UVB it should be replaced.
  • When using this meter to compare different type lamps, due to their different spectral power distributions, the readings should be considered relative rather than absolute. Although higher output lamps of similar SPD's will generally read higher than lower output lamps, ones that peak near 290-300 nm (as does the meter response) will read higher than ones peaking near 313 nm even if the total UVB output of both is the same.
  • Do not subject the meter to extremes in temperature, humidity, shock or dust.
  • Use a dry, soft cloth to clean the intrument. Keep sensor free of oil, dirt, etc.